You are here: Troubleshooting > Error Codes > Errors 80-89 > Error 83

Error 83: Commissioning Mode Feedback Fault

Variable M108

The safety PLC has detected there is a fault with initiating commissioning mode. The PLC must send a signal back to the controller within 0.5 seconds to confirm commissioning mode has been engaged. This may indicate the safety PLC is faulty or faulty wiring. The saw will still operate as normal.

What to do now

Acknowledge the fault to clear.

What to do next

  • If the problem persists, contact Vekta Automation for assistance.